aliagroup
3rd October 2008, 04:45 PM
Price please ask.
ALIAMAG AMC3100 series Converter can be used with AMF series flow tubes in both compact or separate versions.
FEATURES
Three line LCD display for Flow rate/Totalizer
Accuracy of +/-0.2% of reading
Bi-directional flow measurement, current and pulse output
4-20mA auxiliary Input include 4 digit display
99 of times Datalogger function for power on/off
MODBUS/HART communication
SPECIFICATION
Display:
3 lines LCD with illumination
Line 1:
8 digit totalizer for forward flow
8 digit totalizer for reverse flow
8 digit totalizer for difference
Line 2:
4 digit flowrate / Velocity / % / mA / HZ
Line 3:
Parameter / Query / Clr tot / Query LOG
Alarm, Guidance
Unit:
M3/H , L/H , Kg/H , T/H , L/min
M3/min , GPH , GPM
Accuracy:
+/-0.2% of reading (Velocity >= 0.5 m/s)
+/-0.001 m/s (Velocity < 0.5 m/s)
Alarms:
High/Low with open collector output
Rating:
3 to 30 VDC, 20 mA Max.
Communication:
RS 485(MODBUS Protocol)
HART signal
Data Storage:
Operation parameters and totalization figures are stored by EEPROM for more then 10 years
Protection Class:
IP 67 ,Explosion proof
Power Supply:
90-260 VAC, 50/60 Hz
24VDC +/-10%(Option)
Mounting:
Wall mounting
Bracket on 2'' pipe
ALIAMAG AMC3100 series Converter can be used with AMF series flow tubes in both compact or separate versions.
FEATURES
Three line LCD display for Flow rate/Totalizer
Accuracy of +/-0.2% of reading
Bi-directional flow measurement, current and pulse output
4-20mA auxiliary Input include 4 digit display
99 of times Datalogger function for power on/off
MODBUS/HART communication
SPECIFICATION
Display:
3 lines LCD with illumination
Line 1:
8 digit totalizer for forward flow
8 digit totalizer for reverse flow
8 digit totalizer for difference
Line 2:
4 digit flowrate / Velocity / % / mA / HZ
Line 3:
Parameter / Query / Clr tot / Query LOG
Alarm, Guidance
Unit:
M3/H , L/H , Kg/H , T/H , L/min
M3/min , GPH , GPM
Accuracy:
+/-0.2% of reading (Velocity >= 0.5 m/s)
+/-0.001 m/s (Velocity < 0.5 m/s)
Alarms:
High/Low with open collector output
Rating:
3 to 30 VDC, 20 mA Max.
Communication:
RS 485(MODBUS Protocol)
HART signal
Data Storage:
Operation parameters and totalization figures are stored by EEPROM for more then 10 years
Protection Class:
IP 67 ,Explosion proof
Power Supply:
90-260 VAC, 50/60 Hz
24VDC +/-10%(Option)
Mounting:
Wall mounting
Bracket on 2'' pipe